Jeio Tech Laboratory Refrigerators – General Purpose (Solid Doors)

Performance :

  • Fully insulated chamber ensuring minimal chamber’s temperature fluctuation.
  • High thermal efficiency evaporation system, made of low corrosive materials.
  • Optimising defrost systems: innovation auto-defrost system automatically activated on detecting amount of frost accumulated in the evaporator (CLG-150S, CLG-300S, CLG-650S, and CLG-850S only), and no defrost system needed for the CLG-1400S due to its dual refrigerating system.
Category:

Description

Spesification :

  • Chamber Volume (litres) :

    • CLG-150S : 156
    • CLG-300S : 303
    • CLG-650S : 603
    • CLG-850S : 805
    • CLG-1400S :1327
  • Temperature Range (°C) : 2 to 10
  • Refrigerator (Hp) :

    • CLG-150S and CLG-300S : 1/6
    • CLG-650S : 1/4
    • CLG-850S : 1/3
    • CLG-1400S : 1/4 x 2ea
  • No. of Wire Shelves (standard/max.) :

    • CLG-150S : 2/6
    • CLG-300S : 30/11
    • CLG-650S and CLG-850S : 3/17
    • CLG-1400S : 6/34
  • No. of Wire Shelves, Slide (max., optional) :

    • CLG-150S : 4
    • CLG-300S : 7
    • CLG-650S and CLG-850S : 11
    • CLG-1400S : 22
  • No. of Drawer Shelves, Slide (max., optional) :

    • CLG-150S : 3
    • CLG-300S : 5
    • CLG-650S and CLG-850S : 8
    • CLG-1400S : 16
  • Max. Load Per Shelf (kg) :

    • CLG-150S and CLG-300S : 26
    • CLG-650S, CLG-850S, and CLG-1400S : 30
  • Material(s) :

    • Interior : 304 Grade Stainless Steel
    • Exterior : 1mm Powder-Coated Steel
    • Insulation : 60mm foam-polyurethane
  • Dimensions :

    • Internal (w x d x h) : 550 x 580 x 490mm (CLG-150S), 550 x 580 x 1000mm (CLG-300S), 650 x 640 x 1450mm (CLG-650S), 750 x 740 x 1450mm (CLG-850S), and 1430 x 640 x 1450mm (CLG-1400S)
    •  External (w x d x h) : 683 x 791 x 870mm (CLG-150S), 670 x 770 x 1515mm (CLG-300S), 770 x 865 x 1965mm (CLG-650S), 870 x 965 x 1965mm (CLG-850S), and 1550 x 865 x 1965mm (CLG-1400S)
  • Net Weight (kg) : 100 (CLG-150S), 130 (CLG-300S), 210 (CLG-650S), 260 (CLG-850S), and 350 (CLG-1400S)
  • Electrical Requirements (230V, 50 Hz) :

    • CLG-150S : 2A
    • CLG-300S : 2.3A
    • CLG-650S : 4A
    • CLG-850S : 4.2A
    • CLG-1400S : 6A

Convenience :

  • Intuitive and easy-to-operate control panel with VFD and touch-sensitive buttons. Easy temperature unit conversion between °C and °F.
  • Clear observation of stored samples. Built-in fluorescent lighting (except for CLG-150S).
  • High-quality 304 grade stainless steel interior.
  • Efficient internal space use with height adjustable wire shelves.
  • Built-in 50mm diameter cable port for external probes or wires (except for CLG-150S).
  • Dedicated stand with casters and stacking kit for the CLG-150S for use in labs with limited space (optional).
  • Three types of recorders to choose from (optional): dot recorder (6 point), chart recorder (6″, 24 hours/7 days), and thermal line recorder. 

Safety :

  • High/low temperature protection, over-current protection.
  • Open door alarm and automatic fan stop interlocked with door opening for minimisation of heat loss.
  • Keypad lock function, built-in door lock with a key.