Jeio Tech UV Sterilisation Cabinets

Performance :

  • ISO Class 4 (US Class 10) HEPA filter for optimal protection against cross-contamination (average life span of HEPA filter: 3 years – depending on the test room conditions).
  • High-quality polyester fibre pre-filter (with minimal pressure loss and 85% arrestant on the A.F.I. test) for trapping larger particles and increasing the life of the main HEPA filter.
  • Effective sterilisation using a long-life 254mm UV lamp (average life span of UV lamp: 8000 hours).
  • Built-in anti-glare fluorescent lamp minimises shadows and relieves eye strain. 
Category:

Description

Spesification :

  • Air Flow Type : Vertical
  • Max. Air Volume (cmh/cfm) :

    • PW-01 : 557/327
    • PW-11 : 697/408
    • PW-21 : 929/546
  • Min. Air Volume (cmh/cfm) :

    • PW-01 : 167/97
    • PW-11 : 209/121
    • PW-21 : 279/162
  • Laminar Air Flow Velocity (m/s/fpm) : 0.3/60
  • Filter(s) :

    • Air Cleaniness : ISO 14644-1 Class 4
    • HEPA Filter : Typical efficiency of 99.99% at 0.3µm US MIL-STD-282; Micro glass fibre media, particle board, aluminium seperator, neoprene gaskets
    • Pre Filter : Polyester fibres with an efficiency of 85% (A.F.I. Test); AL frame, polyester fibre media
  • Noise Level (dBA) : Typically < 60 dBA at blower speed
  • Material(s) :

    • Work Surface : 10mm thick acrylic resin (clear type)
    • Window (front/side, back):8mm/10mm thick acrylic resin (clear type)
  • Illumination (Intensity) :

    • Fluorescent Lamp (lux) : > 1000
    • UV Density (µW/cm2) : 165 (PW-01), 185 (PW-11), and 330 (PW-21)
  • Illumination (Capacity) :

    • Fluorescent Lamp (w) : 15 x 1ea (PW-01), 20 x 1ea (PW-11), and 30 x 1ea (PW-21)
    • UV Lamp (w) : 15 x 1ea (PW-01), 20 x 1ea (PW-11), and 30 x 1ea (PW-21)
  • Dimensions :

    • Internal (w x d x h) : 700 x 585 x 602mm (PW-01), 880 x 585 x 602mm (PW-11), and 1180 x 585 x 602mm (PW-21)
    • External (w x d x h) : 720 x 605 x 964mm (PW-01), 900 x 605 x 964mm (PW-11), and 1200 x 605 x 964mm (PW-21)
  • Net Weight – body (kg) : 56.2 (PW-01), 64.2 (PW-11), and 77.8 (PW-21)
  • Electrical Requirements (230V) :

    • PW-01 : 50Hz, 1.3A
    • PW-11 : 50Hz, 1.4A
    • PW-21 : 50Hz, 1.5A

Convenience :

  • User-friendly microprocessor-based control panel.
  • Large capacity blower and easy blower speed adjustment by the control panel.
  • Easy-settable digital timer for UV light exposure to deactivate DNA and RNA contaminants (wait off, max. 30 min.).
  • Comfortable front access to cartridge type of filters for easy replacement. 

Safety :

  • Interlocking safety door system shuts off UV light automatically when opening the door.
  • UV-blocking door and side panels made of transparent acrylic resin provides clear inside view.
  • UV over-exposure alarm and over-current protection.