Description
1. Nano Spectrophotometer LNS-102
Specification :
Minimum Sample Size | : 0.5-2.0 µl |
Wavelength Range | : 200-800 nm |
Wavelength Accuracy | : 1 nm |
Wavelength Reproducibility | : 1 nm |
Absorbance Range | : 0-300 Abs |
Absorbance Accuracy | : 1% (at 0.7332 at 350 nm) |
Absorbance Precision | : 0.003 Abs |
Spectral Bandwidth | : None |
Spectral Resolution | : ≤ 3 nm (FWHM at Hg 546 nm) |
Path Length | : 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary) |
Light Source | : Xenon flash lamp |
Life Time of Lamp | : None |
Detector | : 3864-element linear silicon CCD array |
Detection Range | : Nucleic acid up to 3~4500 ng/µl (dsDNA) |
Start-up Time | : None |
Measurement Time | : < 5s |
Overall Dimension | : 200x262x154 mm |
Power | : 12-18 W |
Power Supply | : 24V DC |
Weight | : 2.5 kg |
Catalog No. | : 9241116105 |
Wavelength Accuracy | : Fixed wavelength point |
Features :
- Wavelength range
200nm-800nm - Wavelength accuracy
±1.0nm - Easy user interface
Just drop the sample onto the sample point for direct measurement without any prior dilution. - Low sample volumes
Reduce sample loss and eliminate the need for dilution by using low volumes of samples in 0.5µl to 2.0µl for sample measurement. The appropriate path length can be selected automatically or by manual selection. - Fast measurements
Read-time is typically takes less than5sec per sample without washing cuvettes or dilutes the samples - Convenience and ease of use
Calibration curves, kinetics or ratio measurements are all displayed at the touch of a button at connected computer. - Reliability and robust instrumentation
Press-to-read feature reduces the amount of time .Optics with no moving parts minimizes the incidence of optical misalignmentr
Application :
Labocon Spectrophotometer LNS-100 series can accurately measure double-stranded DNA samples up to 6000ng/ul without dilution.
Spectrophotometer ideally suited for measuring :
- Purified protein analysis (A280).
- BCA Assay analysis of protein.
- Lowry Assay analysis of protein.
- Bradford Assay analysis of protein.
- UV-VIS Full-spectrum Scanning.
2. Nano Spectrophotometer LNS-202
Specification :
Minimum Sample Size | : 0.3-2.0 µl |
Wavelength Range | : 200 – 850 nm |
Wavelength Accuracy | : ±1 nm |
Wavelength Reproducibility | : <±0.2 nm |
Absorbance Range | : 0.002-300 |
Absorbance Accuracy | : 1% (0.75 Abs at 350nm) |
Absorbance Precision | : 0.002 Abs |
Spectral Resolution | : 2 nm (FWHM at Hg 546) |
Path Length | : 0.04 mm, 0.1 mm, 0.2 mm, 1 mm, 2 mm |
Light Source | : Xenon flash lamp |
Life Time of Lamp | : 109 flashes upto 10 years |
Detector | : 2048-element linear silicon CCD |
Detection Range | : Nucleic Acid up to 2-10000 ng/µl (dsDNA); BSA:0.08 mg/ml to 543 mg/ml |
Start-up Time | : < 5s |
Measurement Time | : < 5s |
Overall Dimension | : 210x170x110 mm |
Power | : 30 W |
Power Supply | : 90-250V 50/60Hz |
Weight | : 1.35 kg |
Catalog No. | : 9241139164 |
Features :
- Wavelength range
200nm-850nm - Wavelength accuracy
±1.0nm - Easy user interface
By pipetting, just drop the sample onto the sample point for direct measurement without any prior dilution. - Low sample volumes
Reduce sample loss and eliminate the need for dilution by using low volumes of samples in 0.3µl to 2.0µl for sample measurement. The appropriate path length can be selected automatically or by manual selection. - Fast measurements
Read-time is typically takes less than 5sec per sample without washing cuvettes or dilutes the samples - Convenience and ease of use
Calibration curves, kinetics or ratio measurements are all displayed at the touch of a button at connected computer. - Reliability and robust instrumentation
Press-to-read feature reduces the amount of time .Optics with no moving parts minimizes the incidence of optical misalignmentr - Equipped with a built-in printer
Application :
The LNS-200 series Nano spectrophotometers are efficient enough to read the sample quantity from 0.3µl to 2.0 µl in less than 5sec.; which is suitable for various type of measurement such as :
- Peptides (205nm)
- DNA and RNA (260nm)
- Purified protein (280nm)
- Toxicology assays and industrial dyes (490nm)
- Gold nanoparticles (520nm)
- Colorimetric protein assays
- BCA( 562nm)
- Bradford (595nm)
- Modified Lowry (650nm)
- Optical Density measurements (600 nm)